SPOM, Oxygen: 3kg/s (Full Rodriguez)¶
Description¶
This SPOM is the so-called "Full Rodriguez". It generates 2.975 kg/second of oxygen.
Construction
Atmo sensor, upper (hydrogen): above 250
Atmo sensors, lower (oxygen): above 450
Use gold (or better) for things that can overheat. The upper section can be fully enclosed, as the hydrogen cools the top level. What material to build the liquid pipes out of depends on the temperature of your incoming water. If the incoming water is colder than 70°C you can use the water to cool down the surrounding area by using radiant pipes.
Example
For an introduction to how the SPOM works, see: Oxygen: To know the SPOM is to love the SPOM.
Visualization¶


Oops
I forgot the automation wire from the upper gas pump to the atmo sensor on its right.



Credit¶
Design by: Francis John
Source: "Electrolyzer, SPOM, O2, Oxygen: Tutorial nuggets : Oxygen not included" on YouTube
Note
The SPOM was first introduced to the world by QuQuasar in a post on Klei's forums. This design is by Nicolás Rodriguez (and popularized by Francis John).